    It is designed with super double- capacitor and high power air-cooling motor. 

    More safe operation and more strong power output provided.

    It has multiple functions such as carpet and floor cleaning, wax removing, low-speed polishing, crystal, treatment.

     

    Technical:

    Item No. SC-002
    Voltage 220V-240V
    Power 1100W
    Speed 175rpm/min
    Main cable length 12m
    Base plate diameter 17”
    Gross weight 53.5kg
    Handle packing size 375X126X1133mm
    Main body packing size 540X440X365mm
    Color Blue, dark blue, red, grey
    Accessories Main body, handle, water tank, pad holder, hard brush, soft brush.

    SC-005(2) sc005

     

    The multi-functional floor machine are easy to operate, safe and excellent cleaning effect

    It is especially suitable for cleaning the carpet, floor, low speed polishing for various types of floor and refitting of stone surface for hotels, restaurants, office buildings and exhibition halls.

    The main troubles and how to solve

    NO. Trouble Possible fault reasons How to solve
    1 The motor does not rotate The power cable is not connected correctly.Broken power fuse, power off.The power switch is damaged Check for power wire connectionCheck for power supply and fuseReplace the power switch
    2 The motor startup is slow Start capacitorCircuited or damagedBroken centrifugal switches Replace the start capacitorReplace the centrifugal switch
    3 The motor is weak Run capacitor is damagedThe motor coil is damaged Replace the run capacitor
    4 The motor does not stop after the power switch is disconnected The power switch is damaged Replace the power switch
    5 The motor is jammed, the reducer doesn’t work or severe noise is heard Planetary gears are broken due to abnormal overloading operation Replace the gear

    We can supply all the accessories of those machine, like a screw, like a tank, let you haven’t any worries during the using.  Still can’t solve your problem? Please contact us for your questions, we will kindly reply.